冰研應用股份有限公司Advanced HiVac Application Co., LTD
  

Granville Phillips 275



75 Mini-Convectron® Analog Output or RS-485 Interface
Measuring Range for Air and N2 1x10-4 to 1000 Torr
1x10-4 to 1300 mbar
1x10-2 Pa to 130 kPa
(see notes 1 & 2 below)
Step Size at Minimum Pressure 1x10-4 Torr, 1x10-4 mbar, 1x10-2 Pa
Mounting Position Horizontal preferred
Weight 340 gm (12oz) with 1/8 NPT fitting
Operating Temperature 0 °C to 40 °C ambient, non-condensing
Non-operating Temperature -40 °C to 70 °C
Case Material Aluminum extrusion
Compliance EMC Directive: 2004/108/EC; EN61326-1
Low Voltage Directive: 2006/95/EC; EN61010-1
Basic Analog Version 1 or 2 setpoint relays
Analog Output 0.375 to 5.659 VDC for 0 to 1000 Torr of N2, non-linear
Power Required 11.5 to 26.5 VDC, 0.1 A at 11.5 VDC, 1.6 W max
Connector for 1 relay 11.5 to 26.5 VDC, 0.1 A at 11.5 VDC, 1.6 W max
Connector for 2 relays 11.5 to 26.5 VDC, 0.1 A at 11.5 VDC, 1.6 W max
Digital Interface Version RS-485, 2 setpoint relays
Parameters Adjustable Vacuum and atmosphere calibration, setpoints (value, direction and hysteresis)
Baud Rates 19200 Baud (default value)
Data Format ASCII, 8 data bits, one stop bit, no parity, no handshake (default values)
Power Required 11.5 to 26.5VDC, 0.12 A at 11.5 VDC, 2 W max
Connector 15-pin subminiature-D male, high density
Resolution Least significant digit on each range
Setpoint Relay Configuration Single-pole, double-throw (SPDT)
Contact Rating 1 A at 30 Vdc resistive, AC non-inductive
Range 1x10-3 to 1000 Torr, 1x10-3 to 1300 mbar, 1x10-1 Pa to 130 kPa
Resolution 2 significant digits
Convectron® Gauge
Sensor Materials Gold-plated tungsten
Other Materials Exposed to Gas 304 stainless steel, borosilicate glass, Kovar, alumina, NiFe alloy, polyimide
Internal Volume 35 cm3 (2.14 inch3)
Gauge Bakeout Temperature 150°C maximum, non-operating, with electronics removed

Notes:

  1. Measurements will change with different gases and mixtures. Correction curves for common gases are provided in the instruction manual.
  2. Convectron Gauges are not intended for use with flammable or explosive gases.
275 Mini-Convectron® DeviceNet™ Interface
Measuring Range for Air and N2 1x10-4 to 1000 Torr
1x10-4 to 1300 mbar)
1x10-2 Pa to 130 kPa
(see notes 1 & 2 below)
Step Size at Minimum Pressure 1x10-4 Torr, 1x10-4 mbar, 1x10-2 Pa
Mounting Position Horizontal preferred
Weight 340 gm (12oz) with 1/8 NPT fitting
Operating Temperature 0 °C to 40 °C ambient, non-condensing
Non-operating Temperature -40 °C to 70 °C
Case Material Aluminum Extrusion
Compliance EMC Directive: 2004/108/EC; EN61326-1
Low Voltage Directive: 2006/95/EC; EN61010-1
Display (optional) 3-digit green LED, automatic ranging
(see note 2 below)
Resolution Least significant digit on each range
Setpoint Relay
Configuration Two single-pole, double-throw (SPDT)
Contact Rating 1 A at 30 Vdc resistive, AC non-inductive
Adjustments Value, direction, and hysteresis through software
Range 1x10-3 to 1000 Torr, 1 x 10-3 to 1300 mbar, 1 x 10-1 Pa to 130 kPa
Resolution 2 significant digits
Connector 9-pin D male
DeviceNet™ Interface
Parameters Adjustable Vacuum and atmosphere calibrations, setpoints
Device Type Vacuum/pressure gauge device
Messaging Polled I/O and explicit
Address 0 to 63, selected by using the Low and High address switches
Baud Rates 125K, 250K, or 500K, switch selectable
Connector 5-pin Micro
Convectron Gauge
Sensor Materials Gold-plated tungsten
Other Materials Exposed to Gas 304 stainless steel, borosilicate glass, Kovar, alumina, NiFe alloy, polyimide
Internal Volume 40 cm3 (2.5 in3)
Gauge Bakeout Temperature 150 °C maximum, non-operating, electronics removed

Notes:

  1. Measurements will change with different gases and mixtures.
    Correction curves for common gases are provided in the instruction manual.
    Convectron Gauges are not intended for use with flammable or explosive gases.
  2. For units calibrated in mbar, the output signal continues up to the Full Scale of 1300 mbar, but the digital display does not display past 999 mbar.


 

 

 

 

回上一頁